KANTAFLEX TM Expansion Filler Joint
As per MoRTH Section 2600, Clause 2605. Main components are Copper Expansion Joints, Filler Joint, and Compression Fibre.
  1. Copper expansion joint (2 mm thick) shall be placed slightly below the wearing coat.
  2. Compressible fiber (20 mm thick) shall protect the edges of the copper expansion joint.
  3. Filler Joint (20 mm thick) shall fill the gap upto the top level of the wearing coat.
  4. Sealing compound shall be applied both top and bottom for the perfedt fitment.